19. AIRWAY MANAGEMENT
The priorities of basic life support are airway (A), breathing (B) and circulation (C)
Anaesthetists must be very skilled at airway
management.
All patients must have a careful preoperative
assessment of their airway. The anaesthetist will then decide on a plan to
manage the patient’s airway. The anaesthetist must also decide what alternative
action they will take if the airway is difficult to manage. Finally, the
anaesthetist must be prepared and skilled in managing a patient who cannot be
intubated or ventilated.
28% of deaths related to anaesthesia occur
because the anaesthetist was unable to mask ventilate or intubate.
Careful preoperative evaluation and planning
will prevent morbidity and mortality.
The Unconscious Patient
The unconscious patient or any severely ill
patient lying on their back may have an obstructed airway. The first step in
basic life support is to keep the airway clear. Look, listen and feel. Look to see if the chest is rising and falling with
respiration. Partial or complete obstruction makes the diaphagm muscle work
harder. The abdomen will continue to move but there will be less rise of the
chest (paradoxical movement) and there will be indrawing of the spaces between
the ribs and above the collar bones during inspiration. Listen for airway
noises (stridor). A partially obstructed airway may have noises on inspiration
or expiration. A completely obstructed airway may be silent. Feel for breaths
at the mouth and nose.
Clear the airway. Do not try to clear the airway without looking.
Sweeping a finger “blindly” in the airway may push the obstruction further in.
Turn the patient on their side and check the
airway is clear. In the anaesthetised patient or patients who cannot be turned
onto their side, the airway is kept open by extending the neck and pulling the jaw forwards (jaw thust). The tongue will be lifted forward by the
genioglossus muscle that is attached to the base of the point of the jaw.
If the airway remains obstructed place an artificial
airway (e.g. oropharyngeal airway,
nasopharyngeal airway, laryngeal mask or endotracheal tube).
Continually monitor the patient. Look, listen
and feel. Use a stethoscope to check there is air entry and that it is
bilateral. If available use pulse oximetry. Cyanosis may be an unreliable sign of hypoxaemia. Skin
pigmentation, room lighting and the experience of the observer can affect it.
Cyanosis occurs when there is 5 g/dl of unoxygenated blood. An anaemic patient
may be severely hypoxic without showing cyanosis. A patient with haemoglobin of
15 g/dl would become cyanotic at a SaO2 of 78% (PaO2 44
mmHg). A patient with haemoglobin of 9 g/dl would show cyanosis at a SaO2
of 63% (PaO2 33 mmHg). A patient with haemoglobin less than 9 g/dl
would be likely to die before showing cyanosis.
Changes in heart rate and blood
pressure are late signs of hypoxia.
Artificial Airways
Oropharyngeal airways (Guedel) are
hollow curved plastic devices with a rigid flange. When correctly placed the
curved portion holds the tongue clear of the posterior oropharyngeal wall and
the flange sits against the lips. The correct sized oropharyngeal airway will
reach from the angle of the mouth to the ear. The wrong size oral airway may
worsen obstruction. If the airway is too short it may push the tongue down, if
the airway is too long it may lie against the epiglottis. The airway is
inserted “upside down” (with the concave surface facing up) until the tip is
beyond the end of the tongue. It is then rotated 180 degrees. The anaesthetist
may need to continue to extend the neck and pull the jaw forwards to maintain a
clear airway. A cuffed oropharyngeal airway with a 15 mm connector for
attachment to a breathing system is available. They may not be tolerated if the
patient has an intact gag reflex.
Nasopharyngeal airways are smooth non-cuffed tubes with a flange to prevent
pushing them completely into the nose. Nasopharyngeal airways avoid damage to
the teeth and can be inserted if the mouth cannot be opened, but they may cause
the nose to bleed which may cause further obstruction. They are well tolerated
by awake or sedated patients with an intact gag reflex. An un-cuffed
endotracheal tube with a safety pin though one end may be used as a
nasopharyngeal airway. The correct size nasopharyngeal airway will reach from
the tip of the nose to the tragus of the ear. They must be lubricated before
insertion. Gently insert along the floor of the nostril, perpendicular to the
face (never upwards towards the cribriform plate). If there is resistance to
insertion, gently rotate the nasal airway, try the other nostril or use a
smaller tube.
The laryngeal mask is a spoon-shaped mask attached at 30 degrees to a
connecting tube. When correctly placed it forms a low pressure seal around the
laryngeal inlet. The laryngeal mask provides a more secure airway than mask
ventilation, allows the anaesthetist to attend to other tasks and avoids many
of the complications of endotracheal intubation. It is simple to use. Though
aspiration is uncommon, the laryngeal mask does not protect against aspiration.
An air leak will occur with positive pressure ventilation greater than 15 to 20
cm H-20.
The laryngeal mask is available in sizes 1
(less than 5 kg), 1.5 (5 to 10 kg), 2 (10 to 20 kg), 2.5 (20 to 30 kg), 3 (30
to 50 kg), 4 (small adult), 5 (large adult).
The laryngeal mask is best used for routine
general anaesthesia without muscle relaxation or as an emergency airway device
when unable to intubate or ventilate. There are modified laryngeal masks for
positive pressure ventilation (Proseal
®) and intubation (Fastrach ®).
The Proseal has a larger wedge shaped mask
that creates a better seal, allowing the proseal to be used for positive
pressure ventilation. The Proseal also has a drainage tube, which will direct
regurgitated contents away from the laryngeal inlet.
The Fastrach is a rigid laryngeal mask, which
will direct an endotracheal tube centrally and anteriorly towards the laryngeal
inlet. An endotracheal tube can be passed though a laryngeal mask but the
success is much greater using a Fastrach.
[Laryngeal mask size/endotracheal size:
1/3.5, 2/4.5, 3/5.0, 4/6.0, and 5/7.5]
The laryngeal mask is inserted blindly into
the pharynx. There are several ways of inserting a laryngeal mask. The first
technique is based on how food is swallowed. The patient is placed in the
sniffing position (head extended on the neck and neck flexed on the chest) and
the mouth opened. The tip of a deflated and lubricated laryngeal mask is placed
against the hard palate. The index finger is placed at the join of the cuff and
connecting tube, and the laryngeal mask is pushed around the curve of the hard
palate until resistance is felt. The cuff should be inflated without holding
the tube. If correctly placed, the laryngeal mask will rise about 1.5 cm. The
longitudinal black line along the tube should be in the midline against the
upper lip. Other methods include placing the laryngeal mask in “upside down”
(inlet facing up) and rotating the tube 180 degrees after passing passed the
tongue, like an oropharyngeal airway.
A bite-block, usually folded gauze, is
inserted in the mouth to protect the laryngeal mask from being bitten.
Mask ventilation is used for preoxygenation, short operations (when
there is no risk of aspiration) and for resuscitation. This is the most
important skill an anaesthetist has. Patients do not die because they can’t be
intubated; they die because they can’t be ventilated.
The correct sized mask will fit around the
bridge of the nose and over the cheeks and mouth. The mask is usually held with
the left hand but with difficult mask ventilation the anaesthetist may need to
hold the mask with both hands while an assistant ventilates the patient. An
oropharyngeal or nasopharyngeal airway may help maintain a clear airway.
The mask may be placed over the bridge of the
nose and rolled forward into place. The thumb and index fingers are on the neck
of the mask. The third and fourth fingers are placed along the mandible. These
fingers should not push into the soft tissues of the neck. The little finger is
placed at the angle of the jaw. The jaw should be pulled forward into the mask.
The mask should not be pushed down onto the jaw. This would cause the neck to
flex at the head and obstruct the airway. If there is a leak from one side of
the mask the anaesthetist can roll the mask slightly to one side or ask the
assistant to push the cheek up into the mask.
A mask does not protect against regurgitation
and aspiration.
ENDOTRACHEAL INTUBATION
The first attempt at intubation is usually
the best attempt. The anaesthetist must be prepared before attempting
intubation. Drugs and equipment are checked. The assistant is ready. The
patient is carefully positioned. The anaesthetist must be ready to deal with a
difficult intubation at any time.
The trachea may be intubated with the patient
awake, anaesthetised and breathing spontaneously or anaesthetised and
paralysed. Maintaining spontaneous respiration is safer if the anaesthetist
believes that airway management may be difficult. Endotracheal intubation needs
to be learnt and practised. In an emergency the airway must be clear and the
patient must be ventilated. Consider alternative airway management (e.g.
laryngeal mask, oropharyngeal airway and mask ventilation) if not skilled in
intubation.
Indications
Endotracheal intubation may be required in
several conditions including respiratory arrest, respiratory failure, airway
obstruction, reduced conscious state (Glasgow coma score less than 8),
protection from aspiration, suctioning of the trachea and bronchi, drug
administration, prolonged ventilation, inhalation injury, unstable mid-face fracture,
large flail segment and anaesthesia.
Preoperative Assessment
All patients for anaesthesia must have
careful airway assessment regardless of the planned anaesthetic technique.
Patients receiving local anaesthesia may have complications that require the
anaesthetist to intubate. Mask or laryngeal mask ventilation may be inadequate
and the patient may need intubation. Surgery may become more
complicated/extensive requiring intubation. The anaesthetist must have a plan
for the management of the patient’s airway and a secondary plan to
manage problems with ventilation. The anaesthetist must always be prepared to
establish an emergency airway. Patients must never be given a muscle relaxant
unless the anaesthetist is certain of being able to ventilate them.
Equipment
Correct equipment includes two working
laryngoscopes and a selection of blades, a variety of endotracheal tubes,
introducers for endotracheal tubes (rigid stylets and flexible bougies), Magill
forceps, oral and nasal airways, facemasks, suction, alternative airway (e.g.
laryngeal mask) and an emergency airway (e.g. cricothyroid puncture kit).
Positioning
Position the patient in the sniffing
position. Successful direct laryngoscopy requires alignment of the oral,
pharyngeal and laryngeal axes. The neck should be flexed 25 to 35 degrees at
the chest and extended at the head (atlanto-occiptal joint). This can be
achieved by elevating the head about 10 cm with a firm pillow or pads beneath
the occiput with the shoulders remaining on the table.
The occiput of children less than 2 years of
age naturally extends the head. They may not need a pillow.
Apply monitoring to the patient if
available.
Endotracheal tube
Select the endotracheal tube and laryngoscope.
Modern endotracheal tubes are available in sizes from 2.5 mm internal diameter
(I.D.) to 9.0 mm I.D. in 0.5 mm increments. Adult tubes have a high volume
low-pressure cuff to seal the trachea. The cuff should not be inflated to a
pressure of more than 25 mmHg. This is the perfusion pressure in the tracheal
mucosa. Inflation of the cuff to more than 25 mmHg may cause tracheal mucosa
ischaemia. The pressure in a red rubber endotracheal tube often exceeds 25
mmHg. The narrowest part of the trachea is the cricoid cartilage in children.
Un-cuffed tubes should be used before puberty.
The larger the endotracheal tube the lower
the airway resistance and the less chance that there will be herniation of the
cuff from over inflation but the smaller the tube the less chance of sore thoat
and the easier the intubation. Airway resistance does not increase
significantly unless the tube is less than a size 6.0 mm I.D.
The endotracheal tube should have a hole cut
in the wall opposite the bevelled end (Murphy eye). This allows gas to flow
even if the bevelled end is obstructed.
Laryngoscopes
There are many different types of
laryngoscopes (including McCoy, Bell, Miller and Polio). The standard rigid
laryngoscope consists of a detachable blade with a removable bulb (or
fibreoptic light) that attaches to a battery-containing handle. The blade has a
flange on the left side for displacing the tongue. The blade may be curved
(e.g. Macintosh) or straight (e.g. Miller). The curved blade may present more
room in the mouth as the blade matches the curve of the oropharynx. The
straight blade may be better when mouth opening is vertically limited or the
larynx is anterior. The anaesthetist should be trained in the use of both
blades. When laryngoscopy is difficult with one blade, the other blade may be
useful. Laryngoscope blades are available in different lengths. Adults usually
need a size #3 or #4 Macintosh blade, children less than 8 years of age a size
#2 Macintosh blade and term infants a size #1 Miller blade and premature
infants a size #0 Miller blade.
When choosing the size of the endotracheal
tube and length of the laryngoscope blade remember that it is easier to
intubate with a small tube and long blade than a large tube and a short blade.
Laryngoscopy is performed with the laryngoscope held in the left
hand. The blade is inserted into the right side of the mouth. Be careful not to
pinch the lips or knock the incisor teeth. The assistant can help by pulling
the lower lip out of the way. Be careful that the assistant does not flex the
head while pulling the lip. At the tonsillar pillars sweep the tongue to the
left and identify the uvula. Advance the laryngoscope blade slowly down the
midline over the base of the tongue until the epiglottis is seen. A common
mistake is to insert the blade too far down and into the oesophagus. If unsure,
withdraw the laryngoscope slowly and the epiglottis may fall into view. A
curved blade should have its tip in the vallecula. The tip of a straight blade
is placed over the epiglottis. Exposure of the laryngeal inlet is improved by
lifting the laryngoscope in the direction of the handle. Do not use the blade
as a lever on the teeth and gums. The laryngoscope should only be moved in the
direction of the handle, not back towards the anaesthetist.
Insert the endotracheal tube from the right
corner of the mouth. Rotating the tube 90 degrees clockwise may improve the
view of the larynx. The tip of the endotracheal tube may be difficult to push
pass the arytenoids and the base of the laryngeal inlet. Rotating the tube 90
degrees anti-clockwise may help pass the tube though the laryngeal inlet.
If only the base of the larynx can be seen or
the endotracheal tube cannot be positioned anteriorly to pass though the
larynx, the assistant can help by pressing on the cricoid. The assistant should
push the cricoid backwards, upwards and to the right (BURP). Alternatively the
anaesthetist can push the cricoid until there is a good view of the larynx then
have the assistant hold the cricoid in that position.
The rigid stylet and flexible bougie are excellent intubation aids. The rigid stylet is
placed in the endotracheal tube and the tube is bent into a more useful shape.
Usually the curve at the distal end is increased. The stylet should not extend
beyond the end of the endotracheal tube. It could cause tracheal trauma.
The flexible bougie (gum elastic bougie)
should be 60 cm long with a J shape at the distal tip. It should be soft and
flexible to prevent trauma to the trachea. The flexible bougie is used as a
guide for the endotracheal tube. Perform laryngoscopy. At least the tip of the
epiglottis must be seen but ideally the arytenoids should also be seen. BURP
may help improve the view. Pass the flexible bougie behind the mid point of the
epiglottis with the J tip facing anteriorly. Gently push the flexible bougie in
an anterior direction. If successful, “clicks” may be heard as the tip passes
over the tracheal rings. A tracheal ring or the carina will stop the flexible
bougie. If there are no clicks and the passage of the flexible bougie is not
stopped, then the bougie may be in the oesophagus. If in doubt remove the
bougie, ventilate the patient with 100% oxygen and try again.
Hold the bougie firmly at the level of the
mouth. Pass the endotracheal tube over the bougie until the proximal end of the
bougie emerges. Have the assistant hold the proximal end of the bougie firmly. Maintain
laryngoscopy. Gently push the endotracheal tube down the bougie. The tip of
the tube may be stopped by the arytenoids. Turning the tube 90 degrees
anticlockwise may help.
All patients should be pre-oxygenated for at
least thee minutes.
Nasotracheal Intubation
Nasotracheal intubation may be required for
intraoral surgery. It is contraindicated for patients with a fractured base of
skull, fractured nose and coagulopathy. The patient will require a smaller endotracheal
tube (6.0 to 7.0 mm). Spraying the nose with a vasoconstrictor and warming the
tube in hot water will reduce the incidence of bleeding. The anaesthetist
should check which nostril is patent. The right nostril is preferred, as the
bevel of the endotracheal tube will face the flat septum. This is less likely
to cause trauma. Once in the pharynx, a Magill forceps may be needed to direct
the tube though the laryngeal inlet.
Oesophageal Intubation
Always confirm that the endotracheal tube is
in the trachea. If in doubt pull it out and mask ventilate with 100% oxygen
before trying again.
The cuff should be placed just below the
cords. In an adult the marking on the tube at the lip is usually between 20 and
24 cm.
The best way to assess the tube position is to see the endotracheal tube pass though the cords
and check for the presence of end-tidal carbon dioxide. Look for symmetrical
chest movement and listen for breath sounds on both sides of the chest. Check
that there are no breath sounds over the stomach. Look for vapour condensation
on the inside of the tube with exhalation.
Oesophageal Detector
Unrecognised oesophageal intubation will
cause gastric dilatation, aspiration, hypoxia and death. When capnography is
not available an oesophageal detector device is a simple way of detecting
oesophageal intubation. Oesophageal detector devices work by aspirating air. If
the endotracheal tube is in the trachea, air is easily aspirated. (The trachea
is a rigid structure and will not collapse). It is difficult to aspirate air if
the endotracheal tube is in the oesophagus, as it will collapse.
A 60 ml catheter tip syringe can be connected
to an endotracheal tube connector by a short length of rubber tubing. If the
tube is in the oesophagus there will be resistance with aspiration and the
plunger will return to its original position when released. Aspiration of 30 ml
of air is a good sign that the tube is in the trachea. It is not 100% accurate.
Some false results can occur. If there is distension of the oesophagus or
stomach with air, or if the joins of the oesophageal detector device are not
airtight, there may be aspiration of air. Bronchial intubation, bronchospasm,
tracheal compression, obesity and chonic obstructive airways disease may cause
resistance to aspiration of air.
Failed Intubation
Always have a plan for a failed intubation. Don’t waste time trying to intubate, instead mask
ventilate, re-evaluate and try again. If pulse oximetry is available stop
attempting intubation if the SaO2 falls below 90% and do not try
again until the SaO2 is greater than 95%.
No attempt at intubation should be longer
than 30 seconds.
If the patient is at risk of regurgitation and aspiration, maintain the cricoid pressure. Ideally the patient at risk of aspiration should
have been given suxamethonium and will begin to breathe within 3 to 5 minutes.
If the patient becomes hypoxic before the suxamethonium stops working,
The anaesthetist should be give gentle mask
ventilation whilst maintaining the cricoid pressure. If the patient at risk of
aspiration has unfortunately been given a long-acting muscle relaxant, they
will need cricoid pressure and ventilation by mask until the muscle relaxant
can be safely reversed.
If the first attempt at intubation (less than
30 seconds) fails, mask ventilate the patient. (Always make sure the patient is
oxygenated). Reassess the patient’s position and the equipment. Is the patient
in the sniffing position? Is it the correct size laryngoscope? Would BURP help?
Would an intubation aid help? Can you call for help?
Try to intubate again. If intubation fails
thee times consider abandoning endotracheal intubation.
If endotracheal intubation is abandoned the
anaesthetist must decide how to manage the airway and decide if the
surgery should continue. Alternative airway management to endotracheal
intubation includes mask ventilation, laryngeal mask, Proseal and Fastrach.
Neither will protect against regurgitation (though the Proseal laryngeal mask
offers some protection). Laryngeal masks have the advantage that the
anaesthetist can attempt to pass an endotracheal tube blindly though the
laryngeal mask.
The anaesthetist must also be aware that
because of repeated attempts at intubation the airway may become more difficult
to manage. Airway bleeding and oedema may make mask ventilation more difficult.
If there are surgical complications it may be difficult for the anaesthetist to
manage both an unsecured airway and the surgical complication. Most surgery can
be delayed at least a few hours while the patient is allowed to wake up and an
alternative plan made. Reassess the need for intubation.
Regional anaesthesia may be possible for some
surgery. However the anaesthetist must be aware that rare complications from
regional anaesthesia (e.g. convulsion, high spinal) may require intubation.
Awake Intubation
If the surgery cannot be done under regional
anaesthesia the anaesthetist must decide on a plan for airway management. With
more airway aids and the help of a more experienced anaesthetist it may be
possible to attempt endotracheal intubation again. Alternative airway
management includes awake intubation
or awake surgical or percutaneous tracheostomy.
The aim of awake intubation is to
anaesthetise the upper airway using local anaesthesia in order to pass an
endotracheal tube.
An awake intubation should be performed as an
elective procedure. It is not a good choice of emergency airway management when
intubation fails. It is a good choice when intubation is assessed
preoperatively as being difficult.
Awake intubation can be performed with a
flexible fibreoptic bronchoscope or using direct laryngoscopy. The endotracheal
tube may be placed though the nose or the mouth. The nasal route may be less
stimulating. The patient must be carefully prepared. The patient must be
co-operative. They will need a full explanation of the procedure. Premedication
with intramuscular atropine will dry up oral secretions and improve visibility
but may be uncomfortable for the patient. The patient may require minimal
amounts of sedation but the anaesthetist must be aware that an awake intubation
is performed because the airway may be difficult. If the anaesthetist gives too
much sedation the airway may become obstructed and intubation may be
impossible. It is safer to take more time than give more sedation.
The local anaesthetic can be given topically
or by nerve blocks. Remember not to exceed the recommended maximum dose.
Lignocaine can be “sprayed as you go”. Laryngoscopy must be performed very
slowly. Lignocaine is sprayed over the exposed mucosa and time is allowed for
it to work before advancing. The patient will cough when lignocaine is sprayed
on the cords and down the trachea. Alternatively lignocaine may be nebulised (5
ml of 4%). The patient will often also need some extra sprays.
The nose may be anaesthetised with sprays of
lignocaine with adrenaline or with cocaine (4% up to 2 mg/kg). It is important
to use a vasoconstrictor to reduce the chance of nasal haemorrhage. The
endotracheal tube must be well lubricated.
The airway may be anaesthetised by gargling
4% lignocaine (or a glossopharyngeal nerve block) and then performing superior laryngeal nerve
blocks and a trans-tracheal
injection of local anaesthetic.
A superior laryngeal nerve block will anaesthetise
the supra-glottic structures: 2 to 3 ml of lignocaine is injected between the
greater cornu of the hyoid bone and the thyroid cartilage.
A trans-tracheal injection of 3 ml of 2 %
lignocaine with a 23-gauge needle though the cricothyroid membrane will
anaesthetise the trachea. The needle must be quickly removed because most
patients will cough vigorously.
The glossopharyngeal nerves may be blocked by
5 ml of 1% lignocaine injected into the area where the base of the tongue
touches the palatoglossal fold. The needle must be aspirated to avoid
intravascular injection. Gargling with lignocaine followed by a spray of 10%
lignocaine is equally effective.
If the laryngeal structures are easily seen
during awake laryngoscopy it may be safe to induce general anaesthesia and
intubate the patient. Remember that some patients may depend on the normal
muscle tone in the upper airway to maintain a patent airway and with induction
of anaesthesia the structure of the upper airway may change making intubation
difficult. For example it may be possible to view the larynx with awake
laryngoscopy in a patient with a large intra-oral tumour but with induction of
anaesthesia and loss of airway muscle tone the tumour may move to completely
obstruct the larynx.
Awake blind nasal intubation can be attempted
after adequate local anaesthesia of the airway. A well-lubricated endotracheal
tube is passed though the nose into the hypopharynx. The anaesthetist listens
for breath sounds at the end of the tube. The tube is advanced slowly towards
the maximum breath sounds. If breath sounds disappear the tube has passed into
the oesophagus. The tube is passed into the larynx during inspiration or the
patient is asked to pant which will maintain the cords in an open position.
Extubation
Extubation of patients that were difficult to intubate must be
done with care because they may need to be re-intubated. The patient should be
fully awake, reversed and receive 100% oxygen before removing the tube.
Emergency airway management equipment should be prepared. If in doubt, insert a
bougie or a guide wire though the endotracheal tube and extubate the patient.
The endotracheal tube may then be re-inserted over the bougie if the patient
needs re-intubation.
CAN’T INTUBATE – CAN’T VENTILATE!
Good preparation and careful assessment
should prevent the anaesthetist ever having this nightmare. The anaesthetist
must rapidly establish an emergency airway (cricothyroidotomy).
Cricothyroidotomy
With a cricothyroidotomy the patient can only be oxygenated. Carbon dioxide cannot be removed and respiratory
acidosis will occur. A cricothyroidotomy should be converted to a tracheostomy
as soon as possible. It is not possible to breathe spontaneously though a
cricothyroidotomy.
Use a large intravenous cannula attached to a
high-pressure oxygen source to ventilate the patient. A 12 or 14 gauge
intravenous cannula is connected to a 10 ml syringe half full with liquid (e.g.
saline) and introduced though the cricothyroid membrane until air is aspirated.
Placing saline in the syringe makes it easier to see the air being aspirated.
One hand can hold the trachea between the thumb and index finger. Once air is
aspirated the cannula is advanced off the needle. The syringe with saline
should be re-connected to the cannula and aspirated to confirm the cannula has
entered the trachea.
The cannula can then be connected to an
oxygen source by several methods. It is wise to have a cricothyroidotomy kit
prepared for each operating room. Time may be wasted trying to remember how to
attach the oxygen. A 3 mm endotracheal tube adaptor will connect directly to
the cannula or a 7.5 mm endotracheal tube connector will attach to the barrel
of a 3 ml syringe that will attach to the intravenous cannula. Another
excellent alternative is to attach a thee-way tap to the intravenous cannula.
The correct size oxygen tubing will connect to the opposite side of the
thee-way tap. The tap is turned to open all thee channels. The oxygen supply is
turned up to 12 to 15 litre/minute. The anaesthetist can then intermittently
obstruct the third channel of the thee-way tap with a finger. This will direct
oxygen into the lungs. This method of connection ensures the anaesthetist’s
hand remains in contact with the cannula and patient. There is less chance of
the emergency airway being lost. This method also delivers high volumes of
oxygen.
The anaesthetist should also attempt to
prevent obstruction of the patient’s airway (jaw thust, neck extension,
artificial airway). The gas delivered to the patient will not be able to be
expired if the patient’s airway is totally obstructed. This will cause barotrauma.
|